{"product_id":"tripp-lite-by-eaton-ups-smartpro-120v-3kva-288kw-line-interactive-sine-wave-ups-2u-racktower-extended-run-pre-installed-webcardlx-network-interface-lcd-display-usb-db9-serial-smart3000rmxln","title":"Tripp Lite by Eaton UPS SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS 2U Rack\/Tower Extended Run Pre-installed WEBCARDLX Network Interface LCD Display USB DB9 Serial - SMART3000RMXLN","description":"\u003cdiv\u003e\n\u003ch4\u003e\u003cstrong\u003eGeneral Information\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cli\u003eManufacturer: Eaton Corporation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eManufacturer Part Number: SMART3000RMXLN\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eManufacturer Website Address: http:\/\/www.eaton.com\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBrand Name: Tripp Lite series\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct Series: SmartPro\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct Model: SMART3000RMXLN\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct Name: SMART3000RMXLN UPS System with Pre-installed SNMPWEBCARD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMarketing Information: \u003cb\u003e3kVA\/3kW\/120V Battery Backup for Distributed IT, Telecom or Enterprise Deployments\u003c\/b\u003e\u003cp\u003eThe SMART3000RMXLN provides reliable battery backup and AC power protection for connected devices against blackouts, brownouts, surges and line noise. Unity power factor ensures the most watts possible at each power rating, so you can connect more equipment. Pure sine wave power and unity power factor, even when on battery, means this SmartPro® UPS can be used with sensitive IT equipment, including servers, VoIP phones, data storage and PoE switches. Even if the battery is depleted, the UPS will automatically restart when the power comes back on after an extended outage.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eReliable, Expandable Battery Backup Keeps You Operational Through Power Outages\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Extra runtime is available by connecting up to four optional extended battery modules (BP72VRM2U, sold separately).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eNEMA Outlets Protect Your Connected Components\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eOne L5-30R and six managed 5-20R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two programmable load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePre-Installed LX Platform Network Management Card Allows Remote Access 24\/7\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe WEBCARDLXE network interface enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntuitive Front-Panel Interface for Convenient UPS Operation and Monitoring\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe two-line front-panel LCD monitoring screen features 10 selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAutomatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eAVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMART3000RMXLN maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePremium Protection from EMI\/RFI Line Noise Helps Your Equipment Perform Better\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThis UPS filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI\/RFI filtering also helps your connected components perform better and last longer.\u003c\/p\u003e \u003cp\u003e\u003ca id=\"gfk-spex-minisite\" rel=\"nofollow\" href=\"javascript:void(0)\" onclick=\"javascript:window.open('\/\/content.etilize.com\/mini-site\/en_us\/1024273245.html','_blank','height=800,width=780,resizable=yes,scrollbars=yes,toolbar=no,menubar=no,location=no,directories=no,status=no');return false;\"\u003eMore from the Manufacturer\u003c\/a\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct Type: Line-interactive UPS\u003cbr\u003e\n\u003c\/li\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Information\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cli\u003eAVR: Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePlug\/Connector Type: NEMA L5-30P\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReceptacle Type: \u003cul\u003e\n\u003cli\u003eNEMA L5-30R\u003c\/li\u003e\n\u003cli\u003eNEMA 5-15\/20R\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReceptacle Detail: \u003cul\u003e\n\u003cli\u003e1 x NEMA L5-30R\u003c\/li\u003e\n\u003cli\u003e8 x NEMA 5-15\/20R\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTransfer Time: 5 ms\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEMI\/RFI Noise Filter: Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase\u003cbr\u003e\n\u003c\/li\u003e\n\u003ch4\u003e\u003cstrong\u003ePower Description\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cli\u003eLoad Capacity (VA): 3000 VA\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLoad Capacity (Watt): 2880 W\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInput Voltage: 120 V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: \u003cul\u003e\n\u003cli\u003e110 V AC\u003c\/li\u003e\n\u003cli\u003e115 V AC\u003c\/li\u003e\n\u003cli\u003e120 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInput Frequency: 60 Hz\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput Frequency: 60 Hz\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eWaveform Type: Pure Sine Wave\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSurge Energy Rating: 570 J\u003cbr\u003e\n\u003c\/li\u003e\n\u003ch4\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cli\u003eNetwork Management: SNMP Manageable\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAlarm: \u003cul\u003e\n\u003cli\u003eUPS StartUp\u003c\/li\u003e\n\u003cli\u003ePower Failure\u003c\/li\u003e\n\u003cli\u003eLow Battery\u003c\/li\u003e\n\u003cli\u003eOverload\u003c\/li\u003e\n\u003cli\u003eUPS Fault\u003c\/li\u003e\n\u003cli\u003eRemote Shutdown\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003ch4\u003e\u003cstrong\u003eControls\/Indicators\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cli\u003eStatus Indicators: Network Link\/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). LX Platform Interface Status: Normal Operation (Solid Green); Software Update (Alternating Green\/Orange ~1\/sec); Factory Reset (Alternating Green\/Orange ~2\/sec).\u003cbr\u003e\n\u003c\/li\u003e\n\u003ch4\u003e\u003cstrong\u003eInterfaces\/Ports\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cli\u003eSerial Port: Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUSB: Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003ch4\u003e\u003cstrong\u003eBattery Information\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cli\u003eDC System Voltage: 48 V DC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBackup\/Run Time (Full Load): 3 Minute\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBackup\/Run Time (Half Load): 10 Minute\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Swappable: Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTypical Battery Recharge Time: 5 Hour\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eReplaceable Battery: Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003ch4\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cli\u003eStorage Temperature: 5°F (-15°C) - 122°F (50°C)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum Operating Temperature: 104°F (40°C)\u003cbr\u003e\n\u003c\/li\u003e\n\u003ch4\u003e\u003cstrong\u003ePhysical Characteristics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cli\u003eHeight: 3.50\"\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eWidth: 17.50\"\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDepth: 19\"\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eRack Height: 2U\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eForm Factor: Rack\/Tower\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eWeight (Approximate): 72.80 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003ch4\u003e\u003cstrong\u003eMiscellaneous\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cli\u003ePackage Contents: \u003c\/li\u003e\n\u003cli\u003e3000VA 3000W 120V Line-Interactive UPS\u003c\/li\u003e\n\u003cli\u003eWEBCARDLXE network management card\u003c\/li\u003e\n\u003cli\u003e2 x USB cables\u003c\/li\u003e\n\u003cli\u003eDB9 cable\u003c\/li\u003e\n\u003cli\u003eRack-mounting hardware\u003c\/li\u003e\n\u003cli\u003eTower support stands\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide with safety instructions\u003c\/li\u003e\n\u003cbr\u003e\u003cli\u003eSoftware Included: PowerAlert Software\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: Taiwan\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnvironmentally Friendly: Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnvironmental Compliance: Restriction of Hazardous Substances (RoHS)\u003cbr\u003e\n\u003c\/li\u003e\n\u003ch4\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cli\u003eLimited Warranty: 2 Year\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/div\u003e","brand":"D\u0026H Distributing - EDI","offers":[{"title":"Default Title","offer_id":51881200091422,"sku":"SMART3000RMXLN","price":2111.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/4435\/9966\/files\/1024273245_03d6c9f1-a922-4fea-87ad-83107101b3aa.jpg?v=1778112782","url":"https:\/\/thinkedu.com\/products\/tripp-lite-by-eaton-ups-smartpro-120v-3kva-288kw-line-interactive-sine-wave-ups-2u-racktower-extended-run-pre-installed-webcardlx-network-interface-lcd-display-usb-db9-serial-smart3000rmxln","provider":"ThinkEDU","version":"1.0","type":"link"}